Products
Device technology GasCar Laser HUNTER
GasCar Laser HUNTER - 710004
GasCar Laser HUNTER standard
Pump unit for use with a Laser HUNTER.
Possibility to clean the suction system by backwashing using an integrated compressor.
Additional components are required for a functional system for vehicle-based pipeline
inspection and must be ordered separately:
- Laser HUNTER (item 251220).
- Intake unit & probes
- Accessories, e.g. hoses
- Test system
- Notebook, notebook holder
- GIS software (Esders PI NOTE)
- GPS Receiver
Description
The Esders GasCar Laser HUNTER is part of a modular system in which the sensor technology, as the heart of the system, has been structurally separated from the pump unit. The sensor system is the highly sensitive and selective gas detection and gas measuring device Laser HUNTER. The advantage of this modular design is a high degree of user flexibility, as the Laser HUNTER can also be used for other applications in the process of pipeline network inspection.
The system can detect even the slightest traces of gas when inspecting buried gas pipelines. Measurement, speed and GPS data are recorded in the process. Sampling is carried out via an intake bar mounted in front of the vehicle or via an intake system integrated in the front of the vehicle. In both cases, different probes can be used. The sample is fed from the pump via the intake system to the Laser HUNTER measuring device, where it is analyzed. In the standard variant, the entire gas flow from all eight probes is led to a Laser HUNTER and analyzed there. In the extended variant (GasCar Laser HUNTER plus), two Laser HUNTERs are used. The gas flow from four probes arranged next to each other is led to one of the two Laser HUNTERs, so that the left and right sides of the vehicle can be evaluated separately and possible leaks can be better localized. It does not matter which laser module (single laser or dual laser) is installed in the Laser HUNTER. The measured values are immediately displayed on the notebook. An occurring alarm is indicated acoustically and visually and can also be evaluated by the user.
The GasCar Laser HUNTER is equipped with effective dust filters and water barriers to protect the system from dirt and moisture ingress. For a functional check of the system, a test set with a 1,000 ppm test gas can and automatic test gas supply can be connected. Features
- Pump unit for drawing in the gas flow in standard (one pump) or plus (two pumps) version
- With plus version (GasCar Laser HUNTER plus) intake and evaluation of the gas flow for left and right car side separately possible
- Cleaning of the intake system by backwashing via integrated compressor
- Flexible use of the sensor technology (Laser HUNTER) for further applications possible
Technical data
Power supply | 12 Volt |
---|---|
Sampling pump | flow rate 1,600 l/h per pump |
Weight | 12 kg without display unit |
Dimensions | 370 mm x 290 mm x 500 mm (W x H x D) without Laser HUNTER |
Data interface | USB |
Operating temperature | Outside the car: -20 to +50°C, in the car: 0 to +50°C |